Skip to content
EntireFM engineer commissioning fire alarm interface and emergency egress controls
LIFE SAFETY & STATUTORY PROTECTION

Fire Alarm, Emergency Lighting & Life Safety Systems

Zero-tolerance life safety engineering, addressable fire alarm maintenance, 3-hour emergency lighting discharge testing, and digital compliance registers aligned with the Building Safety Act.

BS 5839-1 Aligned
Alarm Code
BS 5266-1 Compliant
Lighting Code
Digital Golden Thread
Compliance Register
  • ResponseOut-of-hours cover
  • ComplianceStatutory testing & records
  • EstatesCommercial & industrial
  • ScopeHard & soft services
SFG20 Compliance & Statutory Auditing
FIRE ALARMSBS 5839 Detection & Testing
Electrical Power, Switchgear & Lighting Infrastructure
EMERGENCY LIGHTS3-Hour Battery Discharge
Hard FM & Mechanical Engineering Tools
PASSIVE FIREDampers & Compartmentation
Data-Driven CAFM Insights & Reporting
GOLDEN THREADDigital CAFM Logbooks
ZERO-TOLERANCE STATUTORY GOVERNANCE

Uncompromising Life-Safety Engineering Protecting Occupants, Assets & Duty Holders

Fire detection and emergency lighting represent statutory non-negotiables. Under the Regulatory Reform (Fire Safety) Order and the Building Safety Act 2022, building owners and managing agents bear strict personal liability for compliant life-safety systems.

100% certified statutory testing timestamped with qualified engineer sign-off
Full 3-hour duration emergency lighting discharge testing to BS 5266-1
24/7 emergency dispatch for panel faults, sensor isolations, and resets
Digital Golden Thread compliance register archived directly in CAFM
Single-contract operational accountability backed by certified engineering teams.

EntireFM provides complete life-safety lifecycle care. From weekly bell tests and quarterly addressable loop inspections to annual 3-hour battery discharge audits, fire damper drop tests, and dry riser hydrostatic pressure certification.

Every test is logged electronically in EntireCAFM, ensuring your statutory compliance dossier is always inspection-ready.

EntireFM fire alarm and emergency systems inspection

Addressable Fire Alarm & Life Safety Panel Testing

EntireFM On-Site Engineering Operations
BS 5839 & 5266
Safety Standards
CORE LIFE-SAFETY DISCIPLINES

Comprehensive Fire & Emergency Systems Maintenance

Strict adherence to British Standards (BS 5839, BS 5266, BS 9999, BS 9990) delivering robust protection and audit certainty.

EntireFM engineer testing commercial addressable fire alarm panel
BS 5839-1 Compliance
PRIMARY CAPABILITY

Addressable Fire Alarm Testing & Maintenance

Systematic testing of optical smoke sensors, heat detectors, manual call points, sounder beacon arrays, aspirating systems (VESDA), and cause-and-effect interface relays.

Weekly testing rota and quarterly 25% periodic maintenance inspections
100% annual device verification and sound level (dBA) compliance audits
Auxiliary relay interface testing (automatic doors, gas shut-off, plant shutdown)
Full cause-and-effect matrix validation with managing agent sign-off
Learn More About Addressable Fire Alarm Testing & Maintenance
EntireFM engineer testing emergency lighting luminaire battery circuits
BS 5266-1 Life Safety

Statutory 3-Hour Emergency Lighting Discharge Audits

Monthly functional flicker tests and annual 3-hour full duration battery discharge testing across all maintained and non-maintained luminaires, illuminated exit signs, and central battery units.

Monthly key-switch functional testing across all emergency circuits
Annual statutory 3-hour discharge audit with lux level verification
Immediate luminaire battery and LED gear tray remedial replacement
Digital test logbook generation meeting enforcing authority standards
EntireFM technician inspecting commercial ventilation ductwork and motorized fire damper
BS 9999 Passive Fire

Fire Damper Drop Testing & HVAC Smoke Containment

Physical inspection and drop testing of HVAC fusible link and motorized fire dampers in fire barrier walls, clearing debris and testing microswitch feedback to the building management system.

Physical drop testing and thermal fusible link condition assessment
Internal ductwork photographic inspection and access hatch verification
BMS alarm telemetry feedback and motor actuator reset testing
EntireFM engineers inspecting critical plant suppression and distribution infrastructure
BS 9990 & BS EN 15004

Dry Riser Testing & Gaseous Suppression Plant

Hydrostatic pressure testing of dry risers to 12 bar, flow rate testing on wet risers, and annual cylinder weight checks for server room gaseous fire suppression systems.

12-bar hydrostatic pressure testing of dry riser inlet and landing valves
FM-200, Novec 1230 & Inergen gaseous cylinder weight verification
Room integrity fan testing for gaseous enclosure hold times
LIFE SAFETY & STATUTORY REGIMES

The Fire Safety & Life-Safety Matrix

Statutory fire compliance is zero-tolerance. From addressable sensor arrays and 3-hour emergency lighting discharge tests to damper drops and digital golden thread archives, explore how EntireFM protects your estate and duty holders.

EntireFM engineer commissioning commercial addressable fire alarm panel and control wiring
ACTIVE DETECTION & ALERTINGBAFE & FIA Aligned
REGIME 01ACTIVE DETECTION & ALERTING

Addressable Fire Alarm & Detection Networks

Quarterly and annual inspection of optical smoke sensors, rate-of-rise heat detectors, aspirating smoke detection (VESDA), sounder beacon circuits, and auxiliary cause-and-effect interfaces.

Mandatory Inspection & Verification Protocols:
Addressable Loop Impedance & Voltage Verification
Aspirating Smoke Detection (VESDA) Pipework Transit Time
Optical & Thermal Smoke Sensor Sensitivity Testing
Auxiliary Interface Relays (Gas shut-off, lift grounding, access unlock)
Statutory Standard

BS 5839-1:2017 Fire Detection and Fire Alarm Systems for Buildings

Testing Interval

Weekly bell test + Quarterly inspection & 100% annual device test

MAINTAINED ASSET TAXONOMY

Fire & Life Safety Equipment Covered

Our specialist engineers inspect, test, and maintain the complete active and passive fire protection infrastructure across your commercial estate.

SFG20 Compliance & Statutory Auditing

Active Detection & Alerting

Alarm Panels & Sensors
  • Addressable Fire Alarm Control Panels (FACP)
  • Optical Smoke & Thermal Heat Detectors
  • Aspirating Smoke Detection (VESDA Pipework)
  • Manual Call Points (Break Glass Units)
  • Voice Alarm & Sounder Beacon Networks
Statutory & SFG20 Aligned
Electrical Power, Switchgear & Lighting Infrastructure

Egress & Emergency Lighting

Illumination & Evacuation
  • Maintained & Non-Maintained Emergency Luminaires
  • Illuminated Exit Box Signage
  • Central Battery Inverter Units (CBU)
  • Automatic Test Systems (DALI Emergency)
  • Photoluminescent Wayfinding Strips
Statutory & SFG20 Aligned
Hard FM & Mechanical Engineering Tools

Passive Fire & Suppression

Containment & Extinguishing
  • Motorized & Fusible Link Fire Dampers
  • Dry & Wet Fire Riser Inlets and Landing Valves
  • Gaseous Fire Suppression (Novec / FM200)
  • Automatic Opening Vents (AOV Smoke Shafts)
  • Fire Extinguishers & Fire Blankets
Statutory & SFG20 Aligned
STATUTORY METHODOLOGY

Our Fire Compliance Lifecycle

From baseline asset register compilation to automated recurring testing rotas and real-time digital certificate archiving.

01

Site Survey & Asset Audit

Comprehensive physical review of all mechanical, electrical, or fabric assets, recording condition, serials, and statutory status.

DeliverableInitial Asset Condition Register
02

Scope & SLA Engineering

Developing tailored SFG20 maintenance regimes, emergency response bands, and contract milestones for your estate.

DeliverableBespoke Planned Maintenance Schedule
03

Mobilisation & Tagging

Digital QR tagging of all plant assets, CAFM system onboarding, and engineer handover with dedicated contract managers.

DeliverableLive Digital Portal & Logbooks
04

Proactive & Reactive Delivery

Execution of scheduled PPM routines alongside 24/7 technical helpdesk dispatch for urgent repairs and breakdowns.

DeliverableFirst-Time Fix Focus & Real-time Tracking
05

Reporting & Governance

Monthly statutory compliance certification, SLA performance tracking, and strategic capital replacement recommendations.

DeliverableConsolidated Executive Report
COMPLIANCE STRATEGY

Systematic Scheduled Testing Prevents Catastrophic System Failures

Proactive quarterly loop impedance testing and battery replacement ensures 100% luminaire and detector availability.

PROACTIVE STRATEGY

Planned Preventative Maintenance (PPM)

Scheduled routines to prevent downtime and protect asset longevity

Weekly fire alarm bell testing & call point rotation log
Monthly emergency lighting functional flicker tests
Quarterly 25% addressable detector and sounder loop servicing
Annual full 3-hour emergency lighting discharge test with lux readings
Annual fire damper physical drop test and microswitch verification
Annual dry riser hydrostatic 12-bar pressure certification
Goal: Zero Plant StoppagesScheduled Visits
REACTIVE SUPPORT

Reactive Engineering & Emergency Cover

Swift technical triage and rapid engineer dispatch when issues arise

24/7 emergency engineer dispatch for fire alarm panel fault beeps
Rapid resolution of earth faults and open-circuit loop breaks
Post-incident investigation, head replacement, and panel reset
Emergency luminaire replacement following failed discharge tests
Direct Helpdesk: 020 4617 0228Priority Triage
DIGITAL COMPLIANCE DOSSIER

Instant Fire Logbooks & Audit Records in EntireCAFM

Never search for a misplaced paper logbook. All test results, certificates, and remedial job sheets are accessible 24/7 in your client portal.

Digital QR Asset Tagging

Physical barcode/QR scanning at each plant asset ensures engineers physically attend equipment and records precise visit timestamps.

Audit-Ready Digital Certificates

EICR reports, Gas Safety CP12s, F-Gas logs, and emergency lighting certificates are instantly archived and searchable by site.

Live Work Order Triage

Track reactive requests in real-time from initial helpdesk logging through mobile technician dispatch to photographic completion proof.

Monthly Estate Performance Analytics

Automated executive dashboards detailing SLA adherence, first-time fix ratios, statutory compliance percentage, and asset health.

Full data isolation and secure 24/7 web access for authorized facilities and property directors.
Data-Driven CAFM Insights & Reporting
EntireCAFM Operational PortalAsset Intelligence & Compliance Engine
LIVE SYSTEM
Statutory Certificate Archival100% Up to Date
Asset Verification StandardSFG20 Certified
Live Work Order DispatchReal-Time Mobile Sync
Audit History RetentionFull Contract Lifetime
Multi-Site Estate PortalIncluded in Contract
STATUTORY CLARITY

Fire & Life Safety Guidance

Technical & Commercial FAQ

Frequently Asked Questions

Common inquiries regarding contract scopes, SLAs, compliance audits, and onboarding.

Commercial fire alarms require weekly user testing by building staff and periodic quarterly/bi-annual inspection by qualified engineers under BS 5839 standards.

COMMERCIAL CONSULTATION

Discuss Your Fire Safety Compliance

Consult directly with our certified fire safety directors. We provide comprehensive gap analyses, BS 5839/5266 testing schedules, and transparent pricing.

Direct Technical Consultation020 4617 0228

Direct line to fire safety compliance directors and 24/7 emergency dispatch.

Commercial Inquiries Deskenquiries@entirefm.com

Tender documents, RFQ schedules, and bespoke contract specifications.

No obligation technical survey and transparent contract schedule quotation.
Fire & Life Safety Systems

Tell Us About Your Requirement

Provide brief estate details below and a regional engineering manager will review your requirement.

Strict commercial confidentiality. Data protected under UK GDPR.