A practical guide to FM compliance, statutory obligations, inspections, testing, records and evidence — with authoritative sources clearly identified.

Search by topic, building system, regulation or responsibility.
Quick Filter:
Reviewed for UK Legislation 2026
Sourced from Primary Legislation & British Standards
FLAGSHIP GUIDED UTILITY

What do I need to check?

Start with your building, systems and responsibilities
Assessment Scope

Generates an indicative baseline of statutory regimes, testing cadences, and mandatory documents tailored to your estate profile.

7 systems selected
STATUTORY DISCIPLINES

10 Core Compliance Regimes

INTERACTIVE COMPLIANCE ENGINE

Statutory Compliance Checker

Execute an indicative compliance screening across 10 UK statutory regimes. Identify potential documentation gaps, determine responsible persons, and download an action plan.

10 Regimes Evaluated·Instant PDF / CSV Export·Zero Fake Compliance Scores
DOCUMENTARY GOVERNANCE

What evidence should I hold?

Typical evidence · Requirements vary by building, system, risk & statute
Fire Safety & Life SafetyLife of building (current edition plus previous revisions)

Fire Risk Assessment (FRA)

A comprehensive written evaluation of fire hazards, means of escape, compartmentation, and occupant vulnerability. Must record significant findings.

Statutory Basis: Regulatory Reform (Fire Safety) Order 2005 Article 9
Fire Safety & Life SafetyMinimum 3 years

Fire Alarm & Detection Logbook

Physical or digital log recording weekly call point activations, false alarm causes, quarterly engineering visits, and sensor cleaning.

Statutory Basis: BS 5839-1:2017 Clause 48
Electrical InstallationsUntil superseded by next full periodic report

Electrical Installation Condition Report (EICR)

Form BS 7671 condition report detailing circuit schedules, test instrument calibrations, and classification of any defects (C1, C2, C3, FI).

Statutory Basis: Electricity at Work Regulations 1989 Regulation 4(2)
Water HygieneMinimum 5 years

Water Hygiene Logbook & Sentinel Records

Monthly hot and cold temperature records, remedial water action closeouts, showerhead descaling sheets, and microbial test lab certificates.

Statutory Basis: HSE ACOP L8 Paragraph 65
Lifting OperationsMinimum 2 years (or until equipment permanently decommissioned)

LOLER Thorough Examination Certificate

Official inspection certificate from independent competent examiner detailing SWL, safe operation declaration, and category A/B defects.

Statutory Basis: Lifting Operations and Lifting Equipment Regulations 1998 Reg 11
Refrigerant & HVACMinimum 5 years

F-Gas Leak Check Records & System Log

Log documenting refrigerant type, baseline charge (kg and t CO2e), recovered quantities, leak check dates, and technician certification details.

Statutory Basis: Fluorinated Greenhouse Gases Regulations 2015 Regulation 6
Asbestos ManagementPermanently (transferable upon freehold/leasehold disposal)

Asbestos Register & Management Plan (AMP)

Plan recording exact location, extent, and condition of all known or presumed ACMs, with priority scoring and re-inspection audit logs.

Statutory Basis: Control of Asbestos Regulations 2012 Regulation 4
Pressure SystemsLifetime of the pressure vessel

Written Scheme of Examination (WSE)

Certified scheme drafted by a competent person defining inspection intervals and test methods for pressure vessels operating above 0.5 bar.

Statutory Basis: Pressure Systems Safety Regulations 2000 Regulation 8
TESTING FREQUENCY MATRIX

Inspection & Testing Frequencies

SystemRequirement / ActivityFrequencyAuthoritative SourceDuty Holder & Notes
Fire Detection & Alarm SystemManual call-point testing & sounder verificationWeeklyBS 5839-1:2017 Clause 44.2Responsible Person / Building Operator: Rotate through different call points weekly so all zones are tested over a 13-week cycle.
Fire Detection & Alarm SystemCompetent engineer maintenance inspection & battery discharge check6-MonthlyBS 5839-1:2017 Clause 45.3Responsible Person (via competent specialist contractor): Includes sensor head sensitivity checks, sound pressure dB measurements, and standby battery load tests.
Emergency Escape LightingShort duration functional test ("flick test")MonthlyBS 5266-1:2016 Clause 12.4.2Responsible Person / Nominated Competent Person: Switch on test switch briefly to verify every lamp illuminates; log in the emergency lighting register.
Emergency Escape LightingFull-duration discharge test (typically 3 hours)AnnualBS 5266-1:2016 Clause 12.4.3Responsible Person (via competent electrical contractor): Ensure sufficient charging time before building re-occupancy so escape lighting is not left depleted during occupancy.
Fixed Electrical InstallationElectrical Installation Condition Report (EICR)Max 5 Years (Commercial) / Max 3 Years (Industrial)BS 7671:2018+A3:2024 / IET GN3Duty Holder under EAWR 1989: Frequency may be shortened based on environmental harshness, damp, dust, or competent inspector judgment.
Water Hygiene / LegionellaSentinel tap temperature monitoring (hot >50°C, cold <20°C)MonthlyHSE ACOP L8 & HSG274 Part 2 Table 2.1Nominated Responsible Person (Water Hygiene): Cold outlet measured after 2 minutes; hot outlet measured after 1 minute; log temperatures in water register.
Water Hygiene / LegionellaCold water storage tank visual inspection and temperature checkAnnualHSE HSG274 Part 2 Table 2.1Competent Water Hygiene Specialist: Inspect for thermal stratification, sediment accumulation, rodent mesh integrity, and tight-fitting lid.
Passenger Carrying LiftsStatutory Thorough Examination under LOLEREvery 6 MonthsLOLER 1998 Regulation 9(3)(a)(i)Lift Owner / Premises Duty Holder: Must be performed by an independent competent person (e.g. engineering insurance surveyor).
Goods Only Hoists & Lifting EquipmentStatutory Thorough Examination under LOLEREvery 12 MonthsLOLER 1998 Regulation 9(3)(a)(ii)Premises Duty Holder: Applies to equipment not intended for passenger conveyance, pallet hoists, and lifting accessories.
Commercial Gas Appliances & PipeworkGas safety inspection, flue analysis & soundness testingAnnualGas Safety (Installation and Use) Regs 1998 Reg 35Landlord / Building Operator: Must be executed by a Gas Safe registered commercial engineer with relevant non-domestic modules.
Pressure Systems & Air ReceiversExamination in accordance with a Written Scheme of Examination (WSE)Specified in WSE (typically 12–24 months)Pressure Systems Safety Regulations 2000 (PSSR) Reg 8Pressure System User / Owner: A certified competent person must draft and sign the Written Scheme before operation.
Asbestos-Containing Materials (ACMs)Condition re-inspection survey of identified or presumed ACMsAnnualControl of Asbestos Regulations 2012 Regulation 4Statutory Dutyholder: Update the Asbestos Register with surface condition, sealing integrity, and risk score adjustments.
Air Conditioning Systems (>12kW)Energy efficiency inspection and TM44 lodgementEvery 5 YearsEnergy Performance of Buildings (England & Wales) Regs Reg 18Building Controller / System Operator: Must be lodged on the central landmark register by an accredited Air Conditioning Energy Assessor.
Fall Arrest & Mansafe Roof SystemsStructural anchor proof testing and cable re-certificationAnnualBS EN 795 / BS 7883 / Work at Height Regs 2005Premises Duty Holder: Inspect swages, shock absorbers, tension, and chemical anchors before permitting roof access.
Frequencies can vary based on risk assessment, equipment age, manufacturer recommendations, and building use.Open 52-Week Statutory Calendar →
AUDIT ARCHITECTURE

Compliance Gap Review

Clear evidence classifications · Zero arbitrary percentage scores
KNOWN

Documented, valid & evidenced

DUE

Approaching statutory re-inspection

MISSING

No record on file

EXPIRED

Superseded or lapsed interval

UNKNOWN

Duty boundary unestablished

Statutory compliance cannot be reduced to a subjective percentage such as "84% compliant" because a single missing fire door inspection or overdue Legionella risk assessment creates criminal liability regardless of other documented regimes. We evaluate estates on absolute documentary evidence.

INTELLIGENCE SYNC

Recent Regulatory Changes

View Full KNOW Intelligence Feed →
Building Safety Act 2022In Force 2026

Mandatory Occurrence Reporting in force for Higher-Risk Buildings (HRBs). 10-day notice window to BSR.

Source: Building Safety Regulator
F-Gas Phase-Down (EU 2024/573 & UK)Updated 2026

Accelerated quota reductions for HFCs with GWP >2500. New mandatory servicing log criteria.

Source: DEFRA / Environment Agency
Fire Safety (England) RegulationsStatutory Obligation

Quarterly communal fire door checks & annual flat entrance door checks in residential blocks >11m.

Source: Home Office Guidance
PRIMARY STATUTORY REPOSITORY

Legislation & Official Guidance

General Health & Safety·UK Parliament / HSE (1974)·In Force

Health and Safety at Work etc. Act 1974

The primary piece of legislation covering occupational health and safety in Great Britain. Imposes general duties on employers, building owners, and landlords to ensure the safety of employees and visitors.

legislation.gov.uk
Fire Safety·Home Office / Parliament (2005)·Amended / Expanded

Regulatory Reform (Fire Safety) Order 2005 (RRO)

Designates the "Responsible Person" with legal obligations to conduct fire risk assessments, maintain passive/active fire precautions, and formulate emergency evacuation strategies.

legislation.gov.uk
Building Safety·Ministry of Housing, Communities & Local Government (2022)·Staged Implementation

Building Safety Act 2022

Reforms building safety regulations for Higher-Risk Buildings (HRBs ≥18m or ≥7 storeys). Establishes the Building Safety Regulator, Accountable Persons, Golden Thread of information, and mandatory occurrence reporting.

legislation.gov.uk
Electrical Systems·Health and Safety Executive (HSE) (1989)·In Force

Electricity at Work Regulations 1989

Requires electrical systems to be constructed, maintained, and operated in a manner that prevents electrical danger so far as is reasonably practicable.

legislation.gov.uk
Asbestos Management·Health and Safety Executive (HSE) (2012)·In Force

Control of Asbestos Regulations 2012 (Regulation 4)

Regulation 4 places a legal Duty to Manage asbestos in non-domestic premises, requiring dutyholders to identify ACMs, assess condition, maintain an asbestos register, and review the management plan.

legislation.gov.uk
Lifting Equipment·Health and Safety Executive (HSE) (1998)·In Force

Lifting Operations and Lifting Equipment Regulations 1998 (LOLER)

Mandates that lifting equipment for lifting persons undergoes statutory thorough examination by an independent competent person at intervals not exceeding 6 months.

legislation.gov.uk
Pressure Systems·Health and Safety Executive (HSE) (2000)·In Force

Pressure Systems Safety Regulations 2000 (PSSR)

Prevents serious injury from the hazard of stored energy in pressure systems (boilers, air receivers, steam systems). Requires a certified Written Scheme of Examination.

legislation.gov.uk
DEEP-DIVE GUIDES

Compliance Topic Library

Discipline Filter:
Fire & Life SafetyLegal Statutory Duty

Fire Doors & Compartmentation

Fire doors are engineered passive safety assemblies designed to resist the passage of smoke, toxic gases, and flames for a specified period (typically FD30 or FD60), safeguarding protected escape corridors and stairwells.

Responsible Person: The Responsible Person under the Regulatory Reform (Fire Safety) Order 2005 (in residential buildings over 11m, specific quarterly/annual checks fall under the Fire Safety (England) Regulations 2022).
Frequency: Commercial: Routine 6-monthly inspections recommended by BS 9999 / BS 8214. Residential (>11m): Quarterly communal fire doors, annual flat entrance doors per Fire Safety (England) Regs 2022.
Required Evidence: Comprehensive fire door inspection asset register with individual door ID numbers; Per-door defect inspection worksheets recording gaps, seals, closer operation, and hardware condition...
EntireFM Practical Guidance

EntireFM recommends fitting all high-traffic communal fire doors with mechanical push-plates and certified magnetic hold-open devices linked directly to the fire alarm system, eliminating wedging and closer arm damage.

Water HygieneLegal Statutory Duty

Legionella Control & Water Hygiene

Legionella bacteria colonise domestic and industrial water systems at temperatures between 20°C and 45°C. Inhalation of contaminated water aerosol droplets causes Legionnaires’ disease, a potentially fatal pneumonia.

Responsible Person: The Statutory Duty Holder (employer or person in control of premises) and their formally designated Nominated Responsible Person for Water Hygiene.
Frequency: Monthly sentinel temperature checks · Quarterly shower descaling · 6-Monthly calorifier blowdown · Annual tank inspection · Review Legionella Risk Assessment at least biennially or after significant system modification.
Required Evidence: Written Legionella Risk Assessment (LRA) by a competent assessor (e.g. LCA registered); Water Hygiene Logbook containing signed monthly sentinel temperature records...
EntireFM Practical Guidance

EntireFM recommends installing wireless LoRaWAN pipe temperature sensors on sentinel incoming mains and return loops. Continuous 15-minute telemetry eliminates manual logging labour and flags hot/cold crossover heating immediately.

Electrical SystemsLegal Statutory Duty

Electrical Installation Condition Report (EICR)

An in-depth inspection and testing of the fixed electrical wiring, switchgear, distribution boards, earthing, bonding, and circuit protection devices within a building to verify safety against electrical shock and fire.

Responsible Person: The Duty Holder under Regulation 4(2) of the Electricity at Work Regulations 1989 (Employers, Building Owners, Managing Agents).
Frequency: Maximum 5 years for commercial offices, retail, and public buildings; maximum 3 years for industrial facilities. Frequencies may be shortened by competent engineer recommendation.
Required Evidence: Full Electrical Installation Condition Report (EICR) with schedule of inspections and test results; Electrical Installation Certificates (EICs) or Minor Electrical Installation Works Certificates (MEIWCs) for remedial repairs...
EntireFM Practical Guidance

EntireFM recommends conducting infrared thermal imaging surveys of main switchboards annually under normal operational electrical load. Thermography detects loose connections and phase imbalances before they escalate to catastrophic arcing.

Fire & Life SafetyBritish Standard / ACOP

Emergency Lighting Inspection & Discharge Testing

Emergency escape lighting automatically illuminates building exit routes and designated safety equipment in the event of a primary mains power failure.

Responsible Person: The Responsible Person under the Regulatory Reform (Fire Safety) Order 2005.
Frequency: Monthly brief functional test · Annual full 3-hour rated duration test.
Required Evidence: Emergency lighting logbook recording dates, tester name, test duration, and luminaire identification; Annual 3-hour full-duration discharge test certificate signed by a competent engineer...
EntireFM Practical Guidance

EntireFM recommends transitioning to DALI-compatible self-testing emergency luminaires during refurbishment. Automated addressable self-test systems record monthly and annual discharge results directly to a digital log, preventing human error.

Lifting & AccessLegal Statutory Duty

Lifting Equipment & Passenger Lifts (LOLER)

Statutory independent engineering examination of passenger lifts, goods lifts, hoists, window cleaning cradles, and lifting accessories to verify mechanical integrity and prevent collapse or entrapment.

Responsible Person: The Lift Owner, Employer, or Managing Agent with control over the lifting equipment.
Frequency: Thorough Examination every 6 months for passenger carrying equipment (or per an agreed Written Scheme); every 12 months for goods-only lifting equipment.
Required Evidence: Thorough Examination Reports issued by an independent engineering surveyor; Maintenance service logbooks showing routine lubrication, rope checks, and brake adjustments...
EntireFM Practical Guidance

EntireFM emphasizes that a lift maintenance contract does NOT constitute a statutory Thorough Examination. Always ensure independent insurer engineering surveyors conduct the LOLER examination separately from your servicing contractor.

HVAC, Chillers & RefrigerantsLegal Statutory Duty

F-Gas Refrigerant Containment & Leak Testing

Statutory containment rules regulating fluorinated greenhouse gases (HFCs, HFOs) used in commercial chillers, VRF/VRV air conditioning systems, and heat pumps to curb atmospheric global warming emissions.

Responsible Person: The System Operator (the entity exercising actual operational control over the cooling/heating equipment).
Frequency: Systems ≥5 t CO2e: at least every 12 months (24 months if fitted with automatic leak detection). ≥50 t CO2e: every 6 months. ≥500 t CO2e: every 3 months.
Required Evidence: Comprehensive F-Gas system asset register with charge weight (kg) and t CO2e calculations; Leak test inspection records signed by Refcom / F-Gas certified engineers...
EntireFM Practical Guidance

EntireFM notes that under the latest refrigerant phase-down schedules, legacy high-GWP refrigerants (R404A, R410A) face supply constraints and sharp price escalation. Factor R32 or ultra-low GWP R290/R1234ze retrofit planning into your 5-year capital replacement plan.

Professional Statutory Disclaimer & Competent Person Notice

EntireFM provides practical compliance information, inspection schedules, and documentary tools intended to assist facilities managers and property professionals in organizing statutory duties. Requirements vary depending on building classification, occupancy, equipment specification, contractual lease obligations, and site-specific risk assessments. The content on this platform does not constitute formal legal counsel or statutory sign-off. Statutory examinations (e.g. LOLER, PSSR, EICR, Gas Safety) must always be executed by formally qualified competent persons and certified accredited bodies.