The Five Steps to Contractor Risk Assessment
Identify the Hazards
Inspect the physical working area, equipment, materials, and processes. Look beyond obvious risks to identify invisible hazards such as asbestos, toxic gases, buried cables, or structural weaknesses.
Decide Who Might Be Harmed & How
Identify all affected groups: your engineers, client building occupants, cleaning staff, delivery drivers, and members of the public (especially children or vulnerable persons if near public boundaries).
Evaluate Risks & Apply Controls
Determine the likelihood and severity of harm. Apply the Hierarchy of Controls (Elimination -> Substitution -> Engineering -> Admin -> PPE) to reduce risk As Low As Reasonably Practicable (ALARP).
Record Your Significant Findings
Document the hazards, identified risks, control measures, responsible persons, and residual risk scores in an audit-ready format. (Mandatory for employers with 5 or more staff, and required by all FM clients regardless of business size).
Review & Update When Conditions Change
Regularly audit the assessment. Immediately revise controls if new equipment is deployed, building operations alter, or an incident occurs on site.
What Is a Risk Assessment? & How to Write One
Explore our deep guides covering hazard identification, 5x5 scoring, and plantroom case studies.
Understanding the 5x5 Risk Matrix
Risk is mathematically defined as: Risk = Severity (1-5) × Likelihood (1-5).
Acceptable / Manageable
Standard site precautions and basic PPE are sufficient. Work may proceed under normal supervision.
Tolerable with Specific Controls
Formal engineering isolations, permits to work, or physical barriers required. Specific briefing before starting.
Unacceptable / Immediate Stop
Work must not commence. The process must be completely re-engineered or eliminated until residual score drops.
Common Commercial FM Contractor Hazards
Working at Height
Ladders, roofs, plant decks, MEWPs. Falls from height remain the leading cause of fatal injury in UK construction.
Electricity & Live Conductors
Electric shock, burns, arc flash explosions, and power interruption to critical building services.
Hazardous Substances (COSHH)
Refrigerant gases (R410A/R32/R717), solvents, acidic coil cleaners, water treatment biocides.
Hot Works & Fire Inception
Oxy-acetylene brazing, soldering, grinding, roofing torch-on membranes. Strict permit & fire watch required.
Asbestos Containing Materials (ACMs)
Disturbance of insulation boards, pipe lagging, floor tiles in pre-2000 commercial properties.
Lone Working & Confined Spaces
Working isolated in plantrooms, basements, ceiling voids without immediate alarm communication.